Please use this identifier to cite or link to this item:
https://dspace.ffh.bg.ac.rs/handle/123456789/942
Title: | A power interruption technique for determining the difference between electron and gas temperatures in the argon d.c. arc supplied with aqueous aerosol | Authors: | Kuzmanović, Miroslav Antić-Jovanović, Ankica Stoiljković, Milovan Pavlović, Mirjana S. Marinković, Momir |
Keywords: | Aerosol supply;d.c. Plasma;Plasma diagnostics;Power interruption technique | Issue Date: | 1-Jan-2003 | Journal: | Spectroscopy Letters | Abstract: | The difference between electron and gas temperatures in a low current U-shaped d.c. arc with aqueous aerosol supply was studied using a power interruption technique. Monitoring of the temporal evolution of recombination continuum after power switch-off revealed that it was necessary to do a correction of the measured values due to a change in electron concentration. It was shown that the plasma studied was a two temperature type and that the temperature difference ranges from 1850 K to 600 K for arc currents from 3 to 10.5 A, respectively. A comparison with literature results for pure argon arc plasma shows that aerosol introduction reduces the temperature difference. |
URI: | https://dspace.ffh.bg.ac.rs/handle/123456789/942 | ISSN: | 0038-7010 | DOI: | 10.1081/SL-120024580 |
Appears in Collections: | Journal Article |
Show full item record
SCOPUSTM
Citations
5
checked on Oct 28, 2024
Page view(s)
15
checked on Nov 3, 2024
Google ScholarTM
Check
Altmetric
Altmetric