Please use this identifier to cite or link to this item:
https://dspace.ffh.bg.ac.rs/handle/123456789/1502
Title: | Ti-in-biotite geothermometry in non-graphitic, peraluminous metapelites from Crni vrh and Resavski humovi (Central Serbia) | Authors: | Erić, Suzana Logar, Mihovil Milovanović, Dragan Babiĉ, Danilo Adnađević, Borivoj |
Keywords: | Micaschists;Non-graphitic metapelite;Serbia;Ti-in-biotite geothermometer | Issue Date: | 1-Feb-2009 | Journal: | Geologica Carpathica | Abstract: | The study discusses the application of the Ti-in-biotite geothermometer of Henry et al. (2005) to the example of biotites from non-graphitic peraluminous micaschists of Central Serbia. Three petrographically different micaschists were distinguished on the basis of the following mineral assemblages: CV1 (St-Grt-Bt-Ms-Pg-Pl-Qtz), CV2 (Grt-St-Ky-Bt-Ms-Pl-Qtz) and RH (Grt-St-Bt-Ms-Pl-Qtz). Applying different geothermobarometers it was estimated that the studied micaschists were metamorphosed at average temperatures and pressures of 530 °C and 520 MPa (CVlincl), 580 °C and 670 MPa (CV1), 630 °C and 700 MPa (CV2) and 550 °C, 680 MPa (RH). The average temperatures obtained by the Ti-in-biotite method revealed uniform values for CV1 and CV2 micaschists and these values are very similar to the temperatures obtained by other methods. In contrast, the application of Ti-in-biotite geothermometer for RH micaschist yields the temperature difference of 85-110 °C. The variability of temperature is interpreted as a result of a positive correlation of Ti contents and XMg values in RH biotite, which is in disagreement with the principles of the Ti-in-biotite method. The positive Ti-XMg correlation is a result of the compositional variability shown by RH biotites from different samples, which can possibly be related to compositional inhomogeneities of the pelitic protolith. On the other hand, the Ti-in-biotite geothermometer for CV2 biotite gave very uniform temperatures despite variable Ti contents (Ti = 0.260, sd = 0.018 apfu). This is explained as result of the low sensitivity of Ti-in-biotite geothermometer for high Ti concentrations (> 0.25 apfu). |
URI: | https://dspace.ffh.bg.ac.rs/handle/123456789/1502 | ISSN: | 1335-0552 | DOI: | 10.2478/v10096-009-0003-6 |
Appears in Collections: | Journal Article |
Show full item record
SCOPUSTM
Citations
6
checked on Dec 30, 2024
Page view(s)
32
checked on Jan 5, 2025
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.